{"id":228365,"date":"2024-12-13T15:51:50","date_gmt":"2024-12-13T15:51:50","guid":{"rendered":"https:\/\/testoil.com\/?p=228365"},"modified":"2024-12-13T15:51:52","modified_gmt":"2024-12-13T15:51:52","slug":"crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator","status":"publish","type":"post","link":"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/","title":{"rendered":"Crackle Test for Industrial Oil: Simple, but a Great First Line Indicator"},"content":{"rendered":"\n<p>The routine Crackle Test reveals the presence of free or emulsified water, but not dissolved water, in oil. It typically detects water concentrations of around 500 parts per million (ppm) or higher. However, specific oils exhibit different crackle detection limits. Understanding the specific detection limit for the oil being tested is critical for useful results. Here are 5 key factors affecting detection limits:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Oil Type and Composition:<br>o Mineral Oils: Have lower water solubility, so water levels around 500-1000 ppm (or lower) often cause a reaction in the Crackle Test.<br>o Synthetic Oils: Depending on the specific synthetic base, these can have higher water solubility, so the test may not detect water until levels exceed the dissolved water threshold.<br>o Esters and Biodegradable Oils: These oils generally have a higher affinity for water, making the Crackle Test less sensitive unless water content significantly exceeds the saturation point.<\/li>\n\n\n\n<li>Temperature Sensitivity: The test is more effective in oils with a lower saturation threshold for dissolved water, since free water will more readily appear and vaporize.<\/li>\n\n\n\n<li>Viscosity: High-viscosity oils can trap water more effectively, making the Crackle Test less sensitive (unless the oil is heated properly).<\/li>\n\n\n\n<li>Additives: Some additives, such as detergents and dispersants, can emulsify water, making it less likely to indicate free water during the test. This can increase the detection threshold.<\/li>\n\n\n\n<li>Environmental Factors: Ambient humidity and sample preparation can influence the accuracy of the test.<\/li>\n<\/ol>\n\n\n\n<p>Rough Detection Thresholds:<br>\u2022 Mineral Oils: 500 ppm or lower.<br>\u2022 Synthetic Oils (PAOs or esters): 1000 ppm or higher.<br>\u2022 Hydraulic Oils with Water-Absorbing Additives: the Crackle Test may not detect water until it\u2019s significantly over 1000 ppm.<\/p>\n\n\n\n<p>The Crackle Test quickly screens lubricants in engines, gearboxes, hydraulic systems, etc. It involves placing a drop of oil on a hotplate that has been heated to between 320\u00b0 F and 400\u00b0 F. If water is present, it vaporizes instantly, causing audible crackling sounds or visible bubbles. If the crackle test is negative, it means that the level of water is below the detection limit\u2014not necessarily that there is no water.<br>The Crackle Test is a first line test because it is limited to detecting relatively high levels of water contamination (\u2265500 ppm) and cannot measure dissolved water. The test yields a positive\/negative result, but cannot quantify the exact amount.<br>At Eurofins TestOil, if the crackle test indicates the presence of water, a Karl Fischer titration is performed to quantify the water. Learn more.<br>To get started with oil analysis and training visit https:\/\/testoil.com\/company\/contact-us\/; call 216-251-2510; or email sales@testoil.com.<\/p>\n\n\n\n<p>About Eurofins TestOil<br>With more than 30 years of experience in the oil analysis industry, Eurofins TestOil focuses exclusively on assisting industrial facilities with reducing maintenance costs and avoiding unexpected downtime through oil and fuel analysis program implementation. As industry experts in diagnosing oil-related issues in equipment such as turbines, hydraulics, gearboxes, pumps, compressors and diesel generators, Eurofins TestOil provides customers with same-day turnaround on routine oil analysis testing. For more information on partnering with Eurofins TestOil on oil analysis programs or training opportunities visit https:\/\/testoil.com. Contact: Al Yates 216-251-2510; sales@testoil.com.<\/p>\n\n\n\n<p>About Eurofins \u2013 the global leader in bio-analysis<br>Eurofins is Testing for Life. Eurofins is the global leader in food, environment, pharmaceutical and cosmetic product testing, and in discovery pharmacology, forensics, advanced material sciences and agroscience Contract Research services. Eurofins is also a market leader in certain testing and laboratory services for genomics, and in the support of clinical studies, as well as in BioPharma Contract Development and Manufacturing. The Group also has a rapidly developing presence in highly specialised and molecular clinical diagnostic testing and in-vitro diagnostic products.<br>With over 61,000 staff across a network of 940 laboratories in 59 countries, Eurofins\u2019 companies offer a portfolio of over 200,000 analytical methods. Eurofins Shares are listed on Euronext Paris Stock Exchange.<\/p>\n","protected":false},"excerpt":{"rendered":"The routine Crackle Test reveals the presence of free or emulsified water, but not dissolved water, in oil. It typically detects water concentrations of around 500 parts per million (ppm) or higher. However, specific oils exhibit different crackle detection limits. Understanding the specific detection limit for the oil being tested is critical for useful results. Here are 5 key factors&nbsp;<a href=\"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/\" class=\"read-more\">Continue Reading<\/a>","protected":false},"author":4016,"featured_media":228366,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"content-type":"","_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[400,401],"tags":[],"class_list":["post-228365","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-program-management","category-routine-testing","cat-400-id","cat-401-id"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v22.0 (Yoast SEO v24.8) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Crackle Test for Industrial Oil: Simple, but a Great First Line Indicator - TestOil<\/title>\n<meta name=\"description\" content=\"The routine Crackle Test reveals the presence of free or emulsified water, but not dissolved water, in oil. It typically detects water concentrations of around 500 parts per million (ppm) or higher.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Crackle Test for Industrial Oil: Simple, but a Great First Line Indicator\" \/>\n<meta property=\"og:description\" content=\"The routine Crackle Test reveals the presence of free or emulsified water, but not dissolved water, in oil. It typically detects water concentrations of around 500 parts per million (ppm) or higher.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/\" \/>\n<meta property=\"og:site_name\" content=\"TestOil\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/TESTOILanalysis\" \/>\n<meta property=\"article:published_time\" content=\"2024-12-13T15:51:50+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-12-13T15:51:52+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/testoil.com\/wp-content\/uploads\/2024\/12\/IMG_5461-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1799\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Al Yates\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@TESTOILAnalysis\" \/>\n<meta name=\"twitter:site\" content=\"@TESTOILAnalysis\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Al Yates\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/\"},\"author\":{\"name\":\"Al Yates\",\"@id\":\"https:\/\/testoil.com\/#\/schema\/person\/54d1201d8309b2cb818d422739330acc\"},\"headline\":\"Crackle Test for Industrial Oil: Simple, but a Great First Line Indicator\",\"datePublished\":\"2024-12-13T15:51:50+00:00\",\"dateModified\":\"2024-12-13T15:51:52+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/\"},\"wordCount\":643,\"publisher\":{\"@id\":\"https:\/\/testoil.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/testoil.com\/wp-content\/uploads\/2024\/12\/IMG_5461-scaled.jpg\",\"articleSection\":[\"Program Management\",\"Routine Testing\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/\",\"url\":\"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/\",\"name\":\"Crackle Test for Industrial Oil: Simple, but a Great First Line Indicator - TestOil\",\"isPartOf\":{\"@id\":\"https:\/\/testoil.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/testoil.com\/wp-content\/uploads\/2024\/12\/IMG_5461-scaled.jpg\",\"datePublished\":\"2024-12-13T15:51:50+00:00\",\"dateModified\":\"2024-12-13T15:51:52+00:00\",\"description\":\"The routine Crackle Test reveals the presence of free or emulsified water, but not dissolved water, in oil. It typically detects water concentrations of around 500 parts per million (ppm) or higher.\",\"breadcrumb\":{\"@id\":\"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/#primaryimage\",\"url\":\"https:\/\/testoil.com\/wp-content\/uploads\/2024\/12\/IMG_5461-scaled.jpg\",\"contentUrl\":\"https:\/\/testoil.com\/wp-content\/uploads\/2024\/12\/IMG_5461-scaled.jpg\",\"width\":2560,\"height\":1799,\"caption\":\"Crackle Test from Eurofins TestOil\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/testoil.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Crackle Test for Industrial Oil: Simple, but a Great First Line Indicator\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/testoil.com\/#website\",\"url\":\"https:\/\/testoil.com\/\",\"name\":\"TestOil\",\"description\":\"Oil Analysis\",\"publisher\":{\"@id\":\"https:\/\/testoil.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/testoil.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/testoil.com\/#organization\",\"name\":\"Eurofins TestOil\",\"url\":\"https:\/\/testoil.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/testoil.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/testoil.com\/wp-content\/uploads\/2023\/02\/TestOil-01_RGB.png\",\"contentUrl\":\"https:\/\/testoil.com\/wp-content\/uploads\/2023\/02\/TestOil-01_RGB.png\",\"width\":867,\"height\":184,\"caption\":\"Eurofins TestOil\"},\"image\":{\"@id\":\"https:\/\/testoil.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/TESTOILanalysis\",\"https:\/\/x.com\/TESTOILAnalysis\",\"https:\/\/www.linkedin.com\/company\/testoil-laboratory\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/testoil.com\/#\/schema\/person\/54d1201d8309b2cb818d422739330acc\",\"name\":\"Al Yates\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/testoil.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/7a21eb677ce423c15e7819f6f9221e7f34ed956f45c7c0c4f011c3386fcad412?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/7a21eb677ce423c15e7819f6f9221e7f34ed956f45c7c0c4f011c3386fcad412?s=96&d=mm&r=g\",\"caption\":\"Al Yates\"},\"url\":\"https:\/\/testoil.com\/author\/ayates\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Crackle Test for Industrial Oil: Simple, but a Great First Line Indicator - TestOil","description":"The routine Crackle Test reveals the presence of free or emulsified water, but not dissolved water, in oil. It typically detects water concentrations of around 500 parts per million (ppm) or higher.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/","og_locale":"en_US","og_type":"article","og_title":"Crackle Test for Industrial Oil: Simple, but a Great First Line Indicator","og_description":"The routine Crackle Test reveals the presence of free or emulsified water, but not dissolved water, in oil. It typically detects water concentrations of around 500 parts per million (ppm) or higher.","og_url":"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/","og_site_name":"TestOil","article_publisher":"https:\/\/www.facebook.com\/TESTOILanalysis","article_published_time":"2024-12-13T15:51:50+00:00","article_modified_time":"2024-12-13T15:51:52+00:00","og_image":[{"width":2560,"height":1799,"url":"http:\/\/testoil.com\/wp-content\/uploads\/2024\/12\/IMG_5461-scaled.jpg","type":"image\/jpeg"}],"author":"Al Yates","twitter_card":"summary_large_image","twitter_creator":"@TESTOILAnalysis","twitter_site":"@TESTOILAnalysis","twitter_misc":{"Written by":"Al Yates","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/#article","isPartOf":{"@id":"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/"},"author":{"name":"Al Yates","@id":"https:\/\/testoil.com\/#\/schema\/person\/54d1201d8309b2cb818d422739330acc"},"headline":"Crackle Test for Industrial Oil: Simple, but a Great First Line Indicator","datePublished":"2024-12-13T15:51:50+00:00","dateModified":"2024-12-13T15:51:52+00:00","mainEntityOfPage":{"@id":"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/"},"wordCount":643,"publisher":{"@id":"https:\/\/testoil.com\/#organization"},"image":{"@id":"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/#primaryimage"},"thumbnailUrl":"https:\/\/testoil.com\/wp-content\/uploads\/2024\/12\/IMG_5461-scaled.jpg","articleSection":["Program Management","Routine Testing"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/","url":"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/","name":"Crackle Test for Industrial Oil: Simple, but a Great First Line Indicator - TestOil","isPartOf":{"@id":"https:\/\/testoil.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/#primaryimage"},"image":{"@id":"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/#primaryimage"},"thumbnailUrl":"https:\/\/testoil.com\/wp-content\/uploads\/2024\/12\/IMG_5461-scaled.jpg","datePublished":"2024-12-13T15:51:50+00:00","dateModified":"2024-12-13T15:51:52+00:00","description":"The routine Crackle Test reveals the presence of free or emulsified water, but not dissolved water, in oil. It typically detects water concentrations of around 500 parts per million (ppm) or higher.","breadcrumb":{"@id":"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/#primaryimage","url":"https:\/\/testoil.com\/wp-content\/uploads\/2024\/12\/IMG_5461-scaled.jpg","contentUrl":"https:\/\/testoil.com\/wp-content\/uploads\/2024\/12\/IMG_5461-scaled.jpg","width":2560,"height":1799,"caption":"Crackle Test from Eurofins TestOil"},{"@type":"BreadcrumbList","@id":"https:\/\/testoil.com\/program-management\/crackle-test-for-industrial-oil-simple-but-a-great-first-line-indicator\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/testoil.com\/"},{"@type":"ListItem","position":2,"name":"Crackle Test for Industrial Oil: Simple, but a Great First Line Indicator"}]},{"@type":"WebSite","@id":"https:\/\/testoil.com\/#website","url":"https:\/\/testoil.com\/","name":"TestOil","description":"Oil Analysis","publisher":{"@id":"https:\/\/testoil.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/testoil.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/testoil.com\/#organization","name":"Eurofins TestOil","url":"https:\/\/testoil.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/testoil.com\/#\/schema\/logo\/image\/","url":"https:\/\/testoil.com\/wp-content\/uploads\/2023\/02\/TestOil-01_RGB.png","contentUrl":"https:\/\/testoil.com\/wp-content\/uploads\/2023\/02\/TestOil-01_RGB.png","width":867,"height":184,"caption":"Eurofins TestOil"},"image":{"@id":"https:\/\/testoil.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/TESTOILanalysis","https:\/\/x.com\/TESTOILAnalysis","https:\/\/www.linkedin.com\/company\/testoil-laboratory"]},{"@type":"Person","@id":"https:\/\/testoil.com\/#\/schema\/person\/54d1201d8309b2cb818d422739330acc","name":"Al Yates","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/testoil.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/7a21eb677ce423c15e7819f6f9221e7f34ed956f45c7c0c4f011c3386fcad412?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/7a21eb677ce423c15e7819f6f9221e7f34ed956f45c7c0c4f011c3386fcad412?s=96&d=mm&r=g","caption":"Al Yates"},"url":"https:\/\/testoil.com\/author\/ayates\/"}]}},"_links":{"self":[{"href":"https:\/\/testoil.com\/wp-json\/wp\/v2\/posts\/228365","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/testoil.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/testoil.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/testoil.com\/wp-json\/wp\/v2\/users\/4016"}],"replies":[{"embeddable":true,"href":"https:\/\/testoil.com\/wp-json\/wp\/v2\/comments?post=228365"}],"version-history":[{"count":1,"href":"https:\/\/testoil.com\/wp-json\/wp\/v2\/posts\/228365\/revisions"}],"predecessor-version":[{"id":228367,"href":"https:\/\/testoil.com\/wp-json\/wp\/v2\/posts\/228365\/revisions\/228367"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/testoil.com\/wp-json\/wp\/v2\/media\/228366"}],"wp:attachment":[{"href":"https:\/\/testoil.com\/wp-json\/wp\/v2\/media?parent=228365"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/testoil.com\/wp-json\/wp\/v2\/categories?post=228365"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/testoil.com\/wp-json\/wp\/v2\/tags?post=228365"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}